Lennox nomenclature model number.

MODEL NUMBER IDENTIFICATION 1.5 to 5 Tons CH23 Horizontal ... • Lennox designed horizontal indoor coils can easily be installed with most Lennox horizontal furnaces • Applicable to expansion valve or RFCIV systems NOTE - Expansion valve systems ... General Data Model No. CH23-21 CH23-31 CH23-41 CH23-51 CH23-65 CH23-68 Nominal size - Tons ...

Lennox nomenclature model number. Things To Know About Lennox nomenclature model number.

HS29−120 units have two outdoor fans. HS29−180 and HS29−240 units have four outdoor fans. Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity. Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs, and walkways.Economical, High Efficiency Air Handler. The CBX25-060 is designed to provide reliable, efficient cooling and heating performance at a budget friendly price. A direct drive blower motor delivers a consistent flow of air, to keep every room feeling just right. A full insulated cabinet helps contain sound. Energy Efficiency.Back-of-the-napkin business model is slang for a draft business model. Entrepreneurs sometimes jot down ideas on any available surface - including napkins. Slang for a draft busine...FEATURES. Application. − Provides installation versatility and maximum efficiency in cooling performance, air handling and filtering in cooling or heat pump ap plications. − Available in two model styles, upflow supply air discharge (CB17) or horizontal supply air discharge (CBH17). − Equipped with multi−circuit evaporator coils ...

Summary of Contents for Lennox KGB Series. Page 1 KGB SERIES 2 to 7-1/2 ton Service Literature 100004 7 to 26 kW May 2020 KGB024 through 090 The KGB packaged gas units are available in standard cooling efficiency (024, 030, 036, 048 060, 072, 074 and 090). Cooling capacities range from 2 to 7-1/2 tons (7 to 26kW).Lennox Serial Number Nomenclature - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Lennox serial number decoding

Lennox Model Number Nomenclature Máel Coluim III, 'Canmore' Proposals for The International Code of Nomenclature for Cultivated Plants Gardeners' Chronicle Antique Electric Waffle Irons 1900-1960 "The" journal of the Chemical Society of London International code of nomenclature of cultivated plants Tidy's Physiotherapy E-Book Handbook on ...

Aug 28, 2023 · Lennox stamps the model numbers and essential product details on its nameplate. Except for gas and oil furnaces, where the data plate is located inside the cabinet, near the vestibule panel. All Lennox products display the model number outside the unit. Keep on reading the article to know more about Lennox model numbers and other related topics. Model/Part Number KGB048S4D Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255148747 Product Voltage 208/230v 1ph 60 hz Horsepower. 0.5 . SEER. 14 . Heat. 65 Single . Return Opening Horizontal ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ... − Sound rated in the Lennox reverberant sound test room in accordance with test conditions included in ARI Standard 270-95. − Tested in the Lennox Research Laboratory environmental test room. − Rated according to U.S. Department of Energy (DOE) test procedures. Raider® rooftop units from Lennox Commercial are the new standard for cost efficient reliable, efficient rooftop units built for long-lasting performance that can significantly improve indoor environments. 1. Aluminized Steel Heat Exchanger 2. Scroll Compressors 3. Lennox’ Environ™ Coil System 4. Outdoor Coil Fans 5. Heavy Gauge Steel ...The Building Intelligence Center assists home inspectors, commercial building inspectors, contractors, service technicians, insurance providers, home owners, and property managers in decoding the age of mechanical appliances such as furnaces, boilers, air conditioners, heat pumps, packaged rooftop units (RTU's), packaged terminal air conditioners (PTAC's), and water heaters.

Related Manuals for Lennox GCS16 Series. Industrial Equipment Lennox GCS16 Series Manual (134 pages) Gas Heater Lennox Shadowdance LSVFSD-18 Installation And Operation Instructions Manual. Shadowdance series vent-free millivolt dual-listed gas log sets (20 pages)

The characters are all numbers. The first two digits indicate the year the furnace was made. For instance, if the first 2 numbers are 02, the year is 2002, 05 is 2005, 10 is 2010, 18 is 2018, etc. The 3 rd and 4 th numbers represent the month. For instance, 01 is January, 02 is February through 12, which is December. Sample Serial #: 0408 52398.

What do Lennox furnace model numbers mean? The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P. HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics. GCS16-090-350-2Y.The model and serial numbers for your cooling system can be found on the nameplate or sticker, located near the service panel. The nomenclature sticker should have a white background with black letters.tech.lennoxintl.comLennox Model Number Nomenclature lennox-model-number-nomenclature 2 Downloaded from fortworthcanacademy.org on 2020-04-12 by guest Affecting 4 percent of children and 1-2 percent of the general population, epilepsy is one of the most common neurological disorders. The 1st edition of this guide proved to be the only one of its kind,Air resistance tests from Lennox Laboratory air test chamber. 1.5 to 5 Tons FEATURES MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS C 33 - 18 A - 2 F Series Unit Type C = Indoor Coil - Upflow 1 Cabinet Width A = 14-1/2 in. B = 17-1/2 in. C = 21 in. D = 24-1/2 in. Cabinet F - Cased Uncased coils have no designation Metering Device 2 ...On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.

Lennox international inc. furnace transition kit installation instructions (4 pages) Furnace Lennox GSR21Q Series User's Information Manual. Lenoxx electronics user's information manual gas furnace gsr21q, gsr21v (6 pages) Furnace Lennox G43UF SERIES User's Information ManualLennox DMS1 Nomenclature MODEL NUMBER CAPACITY BTUH EVMS1-95V evaporator - HS6-953V Condensing unit 93,000 EVMS1-135V evaporator - HS6-953V Condensing unit 100,000 EVMS1-125V evaporator - HS6-1353V ... Microsoft Word - Lennox_DMS1_Nomenclature.doc Author: shawnn Created Date: MODEL NUMBER IDENTIFICATION K H A 060 S 4 B N 1 Y Brand/Family Voltage K = Landmark® Product Line Unit Type H = Packaged Heat Pump Major Design Sequence A = 1st Generation Nominal Cooling Capacity - Tons 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling Efficiency S = Standard Efficiency Refrigerant Type 4 = R-410A Blower Type Lennox Serial Number Nomenclature - Free download as PDF File (.pdf), Text File (.txt) or read online for free. Lennox serial number decodingKCa. Landmark®Rooftop Units. Standard Efficiency - 60 HZ. 3 to 7.5 Tons Net Cooling Capacity - 36,200 to 90,000 Btuh Optional Electric Heat - 7.5 to 30 kW. MODEL NUMBER IDENTIFICATION K C A 060 S 4 B N 1 Y. Brand/Family K = Landmark®Product Line Unit Type C = Packaged Electric Cooling w/ optional Electric Heat Major Design Sequence A = 1st ...MODEL NUMBER IDENTIFICATION. L . G H 060 H 4 E S 1 Y. Brand/Family. L = E-Series. Unit Type . G = Packaged Gas Heat w/ Electric Cooling . Major Design Sequence. H = 1st Generation. Nominal Cooling Capacity - Tons . 036 = 3 Tons 048 = 4 Tons 060 = 5 Tons 072 = 6 Tons Cooling Efficiency. S = Standard Efficiency H = High Efficiency. Refrigerant ...

2005 Lennox Industries Inc. ... For downflow application, kit number 83M57 (LB−109844A) is required. Kit is not provided with coil blower; order separately. IMPORTANT The Clean Air Act of 1990 bans the intentional vent-ing of refrigerant (CFC’s and HCFC’s) as of July 1, ... Model No. CB29M-21/26 & CB29M-31 CB29M-41 & CB29M-46 CB29M-51 ...

Lennox International Inc. was founded in 1895 in Marshalltown, Iowa, by Dave Lennox, a railroad machine shop owner who invented a riveted steel coal-fired furnace. Today, Lennox manufactures a wide range of heating, ventilation, and air conditioning units. Some of their most commonly replaced parts include: Heat Pumps.Summary of Contents for Lennox KGB Series. Page 1 KGB SERIES 2 to 7-1/2 ton Service Literature 100004 7 to 26 kW May 2020 KGB024 through 090 The KGB packaged gas units are available in standard cooling efficiency (024, 030, 036, 048 060, 072, 074 and 090). Cooling capacities range from 2 to 7-1/2 tons (7 to 26kW).Quality Parts & Supplies. LennoxPros has 1000s of HVAC Parts and Supplies from adapter curbs to welding equipment. Give LennoxPros.com a try or stop by a Lennox Store location near you. Shop Parts & Supplies. Find Lennox OEM repair parts fast. Our Repair Part Finder lets you search by model number, part number, serial number or catalog number.ˇ ˇ ˆ ˇ ˚˘˙ ˝ˇ ˜ '˘ - %ˇ0: %ˇ0: ! %ˇ0: %ˇ0 " ˘˘ -; 4 *5 ˘*˜ =1#00-0-( % + 0 7˚ ˙. a ˇ ˙ˆ%# * + 6 < &˘ 6c(MODEL NUMBER IDENTIFICATION TGA090 H 2 B S 1 Y Major Design Sequence A = 1st Generation B = 2nd Generation C = 3rd Generation E = 4th Generation Brand/Family T = T−Class Product Line Unit Type G = Packaged Gas Heat w/ Electric Cooling Nominal Cooling Capacity − Tons 090 = 7.5 Tons 102 = 8.5 Tons 120 = 10 Tons 150 = 12.5 Tons … You may see revision numbers as high as 14 or even 18. The revision number is very important in repair part identification as a -1 unit may have a different motor than a -8 would. Phase or Voltage Requirement. The P indicates the phase or voltage the unit requires. P equals single phase 208-230 volt where a Y would equal 3 phase 208-230 volt or ... Service Literature. G40UH (X) series units are mid−efficiency gas furnaces. used for upflow or horizontal applications only, manufac-. tured with Lennox Duralok Plus heat exchangers formed of. aluminized steel. G40UH (X) units are available in heating. capacities of 44,000 to 154,000 Btuh and cooling applica-. tions up to 5 tons.We have done the research to provide you with the details about the tonnage of a Goodman air conditioner. You can determine the tonnage of your Goodman air conditioning by dividing the BTU by 12,000. If the information about the BTU is not available, you can check the model number. You will find 0 and two-digit even numbers ranging …

Basically all manufacturers encode the size or tonnage of their systems into the model number. Tonnage is a measure of BTU's in 12,000 BTU increments. For example a 1 ton system would have 12,000 BTU's. A 2.5 ton system would have 30,000 BTU's. These are reflected in the model numbers near the middle and often followed by a letter.

CBA27UHE Upflow/Horizontal Quantum Coil Air Handler, Power Saver Constant Torque. 1.5- to 5-ton capacities; Voltage options - available in 230/1/60, 460/1/60, *575/1/60 ; Quantum Coil enhanced aluminum coil; Lennox Power Saver technology - constant-torque blower motor boosts system efficiency, helping contractors qualify for energy rebates; Suitable for use with R-410A refrigerants

DMAIC Model - The DMAIC model is commonly used in the Six Sigma process. Learn the ins and outs of the DMAIC model and how it applies to business optimization. Advertisement Proce...Model/Part Number CB30M-41-4P Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) Product Voltage 208/230v 1ph 60 hz Gross Weight. 168 LB. Family. CB30M . Cooling Capacity. 3.0 Ton Cooling . Hertz ... I DO NOT have a Lennox Customer Number. CONTINUE close Stock Availability ...click anywhere on this page to return to lennox hvac information at inspectapedia.com. il il il o 88888 . condensing tm-rs chs 21411-1?) 41 hs 21 - high sde streight cool high side …This is a link to a pdf of the Lennox HVAC equipment model number nomenclatures. http://www3.lennox.com/pdfs/Lennox_Model_and_Serial_Nomenclature.pdf60 HZ P A C K A G E D E L E C T R I C / E L E C T R I C. Bulletin No. 210445 July 2008. Supersedes February 2008. 2 to 6 Tons Net Cooling Capacity − 23,400 to 72,000 Btuh Optional Electric Heat − 7.5 to 30 kW. ASHRAE 90.1 COMPLIANT. MODEL NUMBER IDENTIFICATION. TCA060 S 2 B N 1 Y. Major Design Sequence A = 1st Generation B = 2nd Generation ...Visit us at www.lennox.com For the latest technical information, www.lennoxcommercial.com Contact us at 1-800-4-LENNOX ©2019 Lennox Industries, Inc. 14G46 2/19 PC92167 3- to 20-Ton Packaged Ultra-High-Effi ciency Rooftop Units QUICK REFERENCE GUIDE Unit MCA & MOCP Electrical Data (Standard Indoor Fan Motor) LGH/LCH Voltage HP MCA MOCP 036U4EWe have done the research to provide you with the details about the tonnage of a Goodman air conditioner. You can determine the tonnage of your Goodman air conditioning by dividing the BTU by 12,000. If the information about the BTU is not available, you can check the model number. You will find 0 and two-digit even numbers ranging …Lennox (NYSE: LII) is a leader in energy-efficient climate-control solutions. Dedicated to sustainability and creating comfortable and healthier environments for our residential and commercial customers while reducing their carbon footprint, we lead the field in innovation with our cooling, heating, indoor air quality, and refrigeration systems.

Model/Part Number LGH036H4ES Minimum Order Quantity 0.0 Base Unit of Measure Unit(S) EAN / UPC 66255149409 ... I have a Lennox Customer Number.Related Manuals for Lennox GCS16 Series. Industrial Equipment Lennox GCS16 Series Manual (134 pages) Gas Heater Lennox Shadowdance LSVFSD-18 Installation And Operation Instructions Manual. Shadowdance series vent-free millivolt dual-listed gas log sets (20 pages)Lennox model numbers 14= 1 ton 21= 1-1/2 ton 26= 2 ton 31= 2-1/2 ton 41= 3 ton 46= 3-1/2 ton 51= 4 ton 65= 5 ton So, your unit is a two ton model. The HS stands for high side, HP for heat pump. The next two numbers are the series of unit, they generally work up as they introduce new models. Then a dash and the next two digits which are the ...Number and size of filters (in.) Optional Roof Mounting Frame (used with RDE16-41 only) Optional Economizer Dampers Model No. 3 position Modulating Number and size of filters (in.) Optional Ceiling Supply and Return Air Diffusers Step Down Flush Transition 50,000 75,000 38,000 50,000 38,000 75.0%/75.0% 7.8 24,600 2620 10.0 9.4 3 lbs. 3 oz. 9 x ...Instagram:https://instagram. brooks.verifiedreset lci leveling systemhow to cheat on a proctored exam in personhurricane colinz menu 2005 Lennox Industries Inc. ... For downflow application, kit number 83M57 (LB−109844A) is required. Kit is not provided with coil blower; order separately. IMPORTANT The Clean Air Act of 1990 bans the intentional vent-ing of refrigerant (CFC's and HCFC's) as of July 1, ... Model No. CB29M-21/26 & CB29M-31 CB29M-41 & CB29M-46 CB29M-51 ...MODEL NUMBER IDENTIFICATION 120 Minor Revision Number GCS Y Unit Type GCS = Packaged Gas Heat/Cooling Unit 060 1 Cooling Capacity Tons (kW) 024 = 2 (7.0) 030 = 2.5 (8.8) ... NOTE − Due to Lennox' ongoing committment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. craigslist puppies miamihow much do soap opera stars get paid On other Lennox products the plate is mounted on the outside of unit. The sequence of letters and digits in the Lennox model number reflects specific information about the unit. The figures below analyze two typical model numbers. HS26-060-1P HS26 is the Series, 060 is the Capacity, 1P (1) is the Dash Number and (P) is the Power Characteristics.Created Date: 1/23/2003 3:59:56 PM abrams automotive cincinnati 7.5 to 12.5 Tons. Net Cooling Capacity − 86,000 to 138,000 Btuh Gas Input Heat Capacity − 130,000 to 240,000 Btuh ASHRAE 90.1. COMPLIANT. K G A 120S 4 BS 1 Y. Brand/Family K = K Series. Unit Type. G = Packaged Gas Heat w/ Electric Cooling Major Design Sequence A = 1st Generation B = 2nd Generation Nominal Cooling Capacity - Tons 092 = 7.5 ...HS29−120 units have two outdoor fans. HS29−180 and HS29−240 units have four outdoor fans. Direct drive fan(s) moves large volumes of air uniformly through entire condenser coil(s) for high refrigerant cooling capacity. Upward discharge of air reduces operating sound levels and prevents damage to lawns, shrubs, and walkways.